component to read and control an ETA SH system
A configured uart is required.
Example:
eta_sh:
boiler_temperature:
name: Kesseltemperatur (Boiler temp)
fan_speed:
name: Gebläsedrehzahl (Speed of boiler Fan)
unit_of_measurement: RPM
return_temperature:
name: Kesselruecklauf (Boiler water return temp)
buffer_bottom_temperature:
name: Puffer unten (Water buffer bottom temp)
buffer_middle_temperature:
name: Puffer mitte (Water buffer middle temp)
buffer_top_temperature:
name: Puffer oben (Water buffer top temp)
exhaust_temperature:
name: Abgastemperatur (Exhaust temp)
room1_temperature:
name: Raumtemperatur (Room1 temp)
room1_output_temperature:
name: Vorlauf Raum 1 (Water to room1 temp)
outside_temperature:
name: Aussentemperatur (Outside temp)
buffer_load:
name: Pufferladezustand (Buffer load in %)
external_heater_temperature:
name: Externer Brenner (External Oven (expansion, e.g. Oil or Gas)
oxygen_sensor:
name: Restsauerstoff (o2 Sensor Percent / Lambda Sond. Returns 0 when oven off)
heater_status:
name: "Status" Status of the heater,
0: "Tür offen" (Door open)
1: "heizt an" (starting Fire)
2: "in Betrieb" (working)
3: "Übertemperatur" (over temperature Limit)
4: "Glutabbrand" (embers burning)
5: "Feuer aus" (no Fire)
6: "Ausgeschaltet" (heater off)
7: "Störung" (fault)
All sensors are optional.