ath79: fix gigabit link pll-data for EX7300
The device did not appear to be reachable unless the connection were
forced to 100Mb or lower. Revert to previously working pll-data.
Also fix the phy-mode to represent the actual state needed for ethernet
to function.
Reported-by: Moritz Schreiber <moritz@mosos.de>
Signed-off-by: Daniel Gimpelevich <daniel@gimpelevich.san-francisco.ca.us>
[add remark about phy-mode property]
Signed-off-by: David Bauer <mail@david-bauer.net>
(cherry picked from commit ee41b602a2
)
This commit is contained in:
parent
bf800022b2
commit
24fddfa1be
@ -216,7 +216,7 @@
|
||||
mtd-mac-address = <&caldata 0x00>;
|
||||
|
||||
phy-handle = <&phy4>;
|
||||
phy-mode = "rgmii";
|
||||
phy-mode = "rgmii-rxid";
|
||||
|
||||
pll-data = <0x83000000 0x80000101 0x80001313>;
|
||||
pll-data = <0x86000000 0x80000101 0x80001313>;
|
||||
};
|
||||
|
Loading…
Reference in New Issue
Block a user